
Sunday, January 28, 2007
Fun with layer masks

Venturing into narrowband territory

Some objects are rich in H-alpha light, others are not. Thus narrowband imaging is not suited for everything. But when it comes to really faint nebula, this works wonders in bringing out subtle details. I decided on imaging M42 because the entire Orion region is full of H-alpha emissions, and because Orion is well-placed in the sky after sunset this time of year. While logging my mount's tracking as described in the previous post, I took 30 exposures of 3-minutes each at ISO 1600. The result is pretty interesting, but I have much to learn about processing narrowband images. It's tricky because of everything being in the red channel. I still have more work to do on the above image, including layering in some shorter exposures to show some core detail of M42. But it's a good start and I am happy with it. I also have a Baader O-III filter that I will try sometime. One of these days I'll get a sulfur filter and have a full narrowband set for tri-color imaging. Should be fun!
UPDATE: Today I processed some 15-second exposures and did a layer mask in Photoshop to bring out more core detail. Below is the result with one using only the luminance channel and one using RGB.


Saturday, January 27, 2007
Measuring periodic error
Last night we had the first clear night on a weekend in about 6 weeks. The only bad thing about this time of year is that really clear nights usually mean really cold nights. This was no exception - quickly dropping to the 30's not long after sunset. Seeing was average, and transparency was above average. The waxing moon was a little over 50% illuminated. These are the times I like to use for experimentation. This night I decided that I needed to get some good data on the periodic error of my EQ6 mount. This brings up a couple of questions:
1. What the heck is periodic error?
2. Why do I want to spend time measuring it on a clear night?
For the first question, about all I can say is that periodic error has to do with the inaccuracy of the gears that move the mount in right ascension and declination. Gears made for mounts in my price range (i.e. cheap) just aren't made perfect. Actually, no gears are made perfect, but the more money you can spend on a mount, the more precision there is. The shape of the gear has a pattern to it which repeats on each revolution of the gear. Each revolution makes up one period. We measure the movement of the mount over several periods to get a picture of the error in the gear. Modern electronics can adapt to this error and help minimize it.
For the second question, I am measuring the periodic error because I will be sending my mount away in the near future to be treated with a new "dry-film" lubricant that is used by people like NASA to improve the mesh between load-bearing gears. Sounds like high-tech stuff, huh? It's a retired NASA engineer that has developed this service for amateur astronomers, and I have been selected as a beta tester. I'll never know if it improves anything unless I have data showing the performance before the treatment.
So, with a clear night at hand I lugged all my gear outside and tried to remember how everything hooks up. Funny how much you forget after 6 weeks of watching it rain every weekend. Once I got everything running, I pointed the mount at a star near the intersection of the celestial equator and my meridian, and fired up K3CCDTools. It was the first time for me using this software, and I had heard good things about it. After getting things lined up, I started a data log and walked away for a little bit. My mount's gear makes one revolution, or period, in 8 minutes. So, I wanted at least 3 periods to get good data. After that, I pointed the mount over to M42 and started some imaging. This time I used Metaguide since that is what I am comfortable with. K3CCDTools will also guide, but sitting outside in the cold is not the best time to learn something new, especially when you haven't even read the manual. With Metaguide ready to do some autoguiding, I started imaging M42 and went back inside to defrost my toes. Meanwhile, Metaguide was logging data while ImagesPlus was happily snapping away 3-minute exposures of M42.
By midnight I was ready for bed and carried my ice-cold equipment back in the house. This morning I imported the date into Excel and examined the results. Seems like my periodic error is 20 arcseconds from peak to peak. Pretty average for a mount in this price range, and about what I expected. The log file from Metaguide showed the error pattern over a longer time. It's interesting how every third wave in the error plot has a weird shape. It's not yet totally clear what all this means, but at least I have some baseline data upon which to make a comparison. Hopefully after my mount is modified, I can repeat this testing and see some improvement. Let's keep our fingers crossed!

1. What the heck is periodic error?
2. Why do I want to spend time measuring it on a clear night?
For the first question, about all I can say is that periodic error has to do with the inaccuracy of the gears that move the mount in right ascension and declination. Gears made for mounts in my price range (i.e. cheap) just aren't made perfect. Actually, no gears are made perfect, but the more money you can spend on a mount, the more precision there is. The shape of the gear has a pattern to it which repeats on each revolution of the gear. Each revolution makes up one period. We measure the movement of the mount over several periods to get a picture of the error in the gear. Modern electronics can adapt to this error and help minimize it.
For the second question, I am measuring the periodic error because I will be sending my mount away in the near future to be treated with a new "dry-film" lubricant that is used by people like NASA to improve the mesh between load-bearing gears. Sounds like high-tech stuff, huh? It's a retired NASA engineer that has developed this service for amateur astronomers, and I have been selected as a beta tester. I'll never know if it improves anything unless I have data showing the performance before the treatment.
So, with a clear night at hand I lugged all my gear outside and tried to remember how everything hooks up. Funny how much you forget after 6 weeks of watching it rain every weekend. Once I got everything running, I pointed the mount at a star near the intersection of the celestial equator and my meridian, and fired up K3CCDTools. It was the first time for me using this software, and I had heard good things about it. After getting things lined up, I started a data log and walked away for a little bit. My mount's gear makes one revolution, or period, in 8 minutes. So, I wanted at least 3 periods to get good data. After that, I pointed the mount over to M42 and started some imaging. This time I used Metaguide since that is what I am comfortable with. K3CCDTools will also guide, but sitting outside in the cold is not the best time to learn something new, especially when you haven't even read the manual. With Metaguide ready to do some autoguiding, I started imaging M42 and went back inside to defrost my toes. Meanwhile, Metaguide was logging data while ImagesPlus was happily snapping away 3-minute exposures of M42.
By midnight I was ready for bed and carried my ice-cold equipment back in the house. This morning I imported the date into Excel and examined the results. Seems like my periodic error is 20 arcseconds from peak to peak. Pretty average for a mount in this price range, and about what I expected. The log file from Metaguide showed the error pattern over a longer time. It's interesting how every third wave in the error plot has a weird shape. It's not yet totally clear what all this means, but at least I have some baseline data upon which to make a comparison. Hopefully after my mount is modified, I can repeat this testing and see some improvement. Let's keep our fingers crossed!


Monday, January 15, 2007
A new toy!

I can't wait to see how the SPC900NC performs, but I won't know until I get a clear night. The latest extended weather forecast is more depressing than the last time I checked. To top it all off, my wife and I are both suffering from bad colds right now. That's why I am sitting at home on a Monday instead of being at work. Now it's starting to rain a little - time to go read a book, or sleep!
Saturday, January 13, 2007
Time for some indoor projects...



Most of the higher-end CCD cameras are cooled, so I thought: why not give it a try on this one? I had most everything I needed already: some thermoelectric cooling modules (also called Peltier devices) and a CPU cooling fan. Now I just needed a "cold plate" - something to transfer heat away from what we want to be cold. I bought some aluminum square tube that had inside dimensions the same as the camera. It wasn't quite that easy and I ended up cutting off one side of the square to make things easier to file down to size. The thermoelectric cooler (from Melcor) was bonded to the CPU cooler heat sink, and then to the cold plate, using thermal epoxy. Some rubber sheet material from Hobby Lobby was placed between the heat sink and cold plate for insulation. The only remaining issue was the DC power for everything. The fan on the CPU cooler needed 12V and the thermoelectric cooler needed 5V. That turned out to be an easy one - I picked up a high-capacity computer power supply that was less than $20 after a big rebate. The final touch was some Molex connectors and I was ready for testing. I decided to use 5-minute exposures as a test. First, I let the DMK take about an hour's worth of 5-minute dark frames without the cooling module turned on. Then, I turned on the cooling module and let it take another hour of exposures. The results seem pretty good and I am anxious to get out and try this under some real imaging, if the weather ever clears out. Below is a comparison between the last uncooled exposure taken and the last cooled exposure taken. Noise is reduced and we are left with hot pixels and some sort of glow in the corner that I haven't figured out yet.


Sunday, January 7, 2007
Gotta love this weather!

Subscribe to:
Posts (Atom)